Modular 3-phase intelligent, true on-line UPS system provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In N+1 configuration, it provides three self-contained, redundant 20kVA power modules that can be hot-swapped (load remaining powered) if maintenance is required. In 1+1 configuration, two SU60KX models connected in parallel can provide fail-safe redundancy (two 60kVA models supporting 60kVA load) or increased capacity (two 60kVA models supporting 120kVA load). Large capacity 60,000VA/48,000W UPS continually converts incoming AC power into filtered DC power and then resynthesizes it back into AC power with pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types. High input power factor, advanced IGBT inverter technology and digital signal processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio).
- N+1 configuration, if maintenance is required, three self-contained, redundant 20kVA power modules can be hot-swapped with load remaining powered
- 1+1 configuration, two SU40KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
- High input power factor, advanced IGBT inverter technology and digital signal processor (DSP) technology produce low input total harmonic distortion (THDi)
- Low THDi (less than 3%) reduces installation costs by allowing 1:1 generator sizing
- Extremely efficient operation (up to 97%) saves money by reducing electricity consumption
- True on-line, double-conversion UPS with IGBT technology provides pure sine wave AC output at all times
- Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
- Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
- 60,000VA/48,000W power capacity with 3-phase, hardwire input/output connections
- 173 to 300V/276 to 477Vac Wide input voltage correction range
- Internal power and battery modules are combined in a single small-footprint tower compartment