SmartOnline 40kVA Modular 3-Phase UPS System, On-line Double-Conversion International UPS

Model: SU40KX

  • N+1 configuration, if maintenance is required, two self-contained, redundant 20kVA power modules can be hot-swapped with the load remaining powered
  • 1+1 configuration, two SU40KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
  • High input power factor, advanced IGBT inverter technology and digital signal processor (DSP) technology produce low input total harmonic distortion (THDi)
  • Low THDi (less than 3%) reduces installation costs by allowing 1:1 generator sizing
  • Extremely efficient operation (up to 97%) saves money by reducing electricity consumption
Compare
Project List
Product Info
Tech Specs
Documents
Accessories
Modular 3-phase intelligent, true on-line UPS system provides 100% system availability with N+1 modular architecture and 1+1 parallel capability. In N+1 configuration, it provides two self-contained, redundant 20kVA power modules that can be hot-swapped (load remaining powered) if maintenance is required. In 1+1 configuration, two SU40KX models connected in parallel can provide fail-safe redundancy (two 40kVA models supporting 40kVA load) or increased capacity (two 40kVA models supporting 80kVA load). Large capacity 40,000VA/32,000W UPS continually converts incoming AC power into filtered DC power, and then resynthesizes it back into AC power with pure sine wave. Perfectly regulated, continuous sine wave output with zero transfer time assures compatibility with all equipment types. High input power factor, advanced IGBT inverter technology and digital signal processor (DSP) technology produce less than 3% input total harmonic distortion (THDi). With low THDi, generators run cooler and last longer, allowing managers to save installation costs by installing a generator with a capacity equal to the equipment load (1:1 ratio).
  • N+1 configuration, if maintenance is required, two self-contained, redundant 20kVA power modules can be hot-swapped with the load remaining powered
  • 1+1 configuration, two SU40KX can be connected in parallel to provide either fail-safe redundancy or increased capacity
  • High input power factor, advanced IGBT inverter technology and digital signal processor (DSP) technology produce low input total harmonic distortion (THDi)
  • Low THDi (less than 3%) reduces installation costs by allowing 1:1 generator sizing
  • Extremely efficient operation (up to 97%) saves money by reducing electricity consumption
  • True on-line, double-conversion UPS with IGBT technology provides pure sine wave AC output at all times
  • Maintains continuous operation with zero transfer time through blackouts, voltage fluctuations and surges
  • Removes harmonic distortion, electrical impulses, frequency variations and other hard-to-solve power problems
  • 40,000VA/32,000W power capacity with 3-phase, hardwire input/output connections
  • 173 to 300V/276 to 477Vac Wide input voltage correction range
  • Internal power and battery modules are combined in a single small-footprint tower compartment
 